1 / 3
| Model | LA-1KS-1-1 |
LA-1KS-2-1 |
LA-1KS-1-2 |
LA-1KS-2-2 |
|||||
| Continuous Power | 1000W |
||||||||
| Peak Power | 2000W |
||||||||
| DC Voltage | DC12V |
DC24V |
DC12V |
DC24V |
|||||
| AC Voltage | 100VAC or 110VAC or 120VAC ± 3V |
220VAC or 230VAC or 240VAC ± 3V |
|||||||
| No Load Current Draws | 1A |
0.5A |
1A |
0.5A |
|||||
| Max AC Input Current | 8.5A |
4.5A |
|||||||
| DC Voltage Range | 10-15.5V |
20-31V |
10-15.5V |
20-31V |
|||||
| Low Voltage Alarm | Lo0: 10.5V |
11V ± 0.3V |
Lo0: 21V |
22V ± 0.3V |
Lo0: 10.5V |
11V ± 0.3V |
Lo0: 21V |
22V ± 0.3V |
|
Lo1: 10.8V |
11.3V ± 0.3V |
Lo1: 21.6V |
22.6V ± 0.3V |
Lo1: 10.8V |
11.3V ± 0.3V |
Lo1: 21.6V |
22.6V ± 0.3V |
||
Lo2: 11.3V |
11.8V ± 0.3V |
Lo2: 22.6V |
23.6V ± 0.3V |
Lo2: 11.3V |
11.8V ± 0.3V |
Lo2: 22.6V |
23.6V ± 0.3V |
||
| Low Voltage Shut Down | Lo0: 10.5V |
10.5V ± 0.3V |
Lo0: 21V |
21V ± 0.3V |
Lo0: 10.5V |
10.5V ± 0.3V |
Lo0: 21V |
21V ± 0.3V |
|
Lo1: 10.8V |
10.8V ± 0.3V |
Lo1: 21.6V |
21.6V ± 0.3V |
Lo1: 10.8V |
10.8V ± 0.3V |
Lo1: 21.6V |
21.6V ± 0.3V |
||
Lo2: 11.3V |
11.3V ± 0.3V |
Lo2: 22.6V |
22.6V ± 0.3V |
Lo2: 11.3V |
11.3V ± 0.3V |
Lo2: 22.6V |
22.6V ± 0.3V |
||
| Low Voltage Alarm Recovery | Lo0: 10.5V |
11.3V ± 0.3V |
Lo0: 21V |
22.6V ± 0.3V |
Lo0: 10.5V |
11.3V ± 0.3V |
Lo0: 21V |
22.6V ± 0.3V |
|
Lo1: 10.8V |
11.6V ± 0.3V |
Lo1: 21.6V |
23.2V ± 0.3V |
Lo1: 10.8V |
11.6V ± 0.3V |
Lo1: 21.6V |
23.2V ± 0.3V |
||
Lo2: 11.3V |
12.1V ± 0.3V |
Lo2: 22.6V |
24.2V ± 0.3V |
Lo2: 11.3V |
12.1V ± 0.3V |
Lo2: 22.6V |
24.2V ± 0.3V |
||
| Low Voltage Protection Recovery | Lo0: 10.5V |
12V ± 0.3V |
Lo0: 21V |
24V ± 0.3V |
Lo0: 10.5V |
12V ± 0.3V |
Lo0: 21V |
24V ± 0.3V |
|
Lo1: 10.8V |
12.3V ± 0.3V |
Lo1: 21.6V |
24.6V ± 0.3V |
Lo1: 10.8V |
12.3V ± 0.3V |
Lo1: 21.6V |
24.6V ± 0.3V |
||
Lo2: 11.3V |
12.8V ± 0.3V |
Lo2: 22.6V |
25.6V ± 0.3V |
Lo2: 11.3V |
12.8V ± 0.3V |
Lo2: 22.6V |
25.6V ± 0.3V |
||
| Over Voltage Shut Down | 15.7V ± 0.3V |
31.5V ± 0.5V |
15.7V ± 0.3V |
31.5V ± 0.5V |
|||||
| Over Voltage Recovery | 15.3V ± 0.3V |
29.5V ± 0.5V |
15.3V ± 0.3V |
29.5V ± 0.5V |
|||||
| Frequency | 50HZ ± 0.5HZ or 60HZ ± 0.5HZ |
||||||||
| Output Waveform | Pure Sine Wave |
||||||||
| AC Regulation | THD < 3% (Linear load) |
||||||||
| Output Efficiency | up to 91% |
||||||||
| Remote Control (Optional) | Cable length: 15m is available. |
||||||||
| Power-Saving mode | The power saving mode will be activated when the output power is less than 5W. When output power is more than 10W, the inverter will automatically return to normal status. |
||||||||
| Ignition Function | Connect vehicles battery (or connect positive pole of vehicles' STARTER). The inverters start simultaneously When the vehicles start; The inverters will shut down meantime when the vehicles shut down. |
||||||||
| Protection Function | Low voltage alarm |
code: F05 |
Buzzer sounds and fault light turns red |
||||||
Low voltage shutdown |
code: F01 |
Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) |
|||||||
Over input voltage protection |
code: F02 |
Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) |
|||||||
over load alarm |
code: F06 |
Buzzer sounds and fault light turns red when output power is overloaded around 110%. But the BUZZ and F06 code will not occurred when the output power drop to a normal level within 20ms. |
|||||||
Over load protection |
code: F03 |
The inverter shutdown when output power is overloaded around 120%, it need to be recovered by hand. |
|||||||
Over temperature alarm |
code: F07 |
Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90 ± 5 °C). |
|||||||
Over temperature protection |
code: F04 |
The inverter will automatically return to normal status when the internal temperature drops to 80 ± 5 °C. |
|||||||
Short circuit protection |
code: F03 |
Recover by hand |
|||||||
Reverse polarity protection |
Built-in fuse |
||||||||
AC input overload protection |
code: F09 |
The fan will start to work when the relay temperature is up to 60 ± 5 °C; but it will stop to work when the relay temperature drops to 50 ± 5 °C. The unit will alarm, and no AC output when relay temperature is up to 75 ± 5 °C; But it will auto recover when the relay temperature drops to normal value. |
|||||||
| Fuse | Internal |
USB port |
5V, 2.1A |
||||||
| Working Temperature | -10°C -- +50°C |
Production Size |
330x150x78mm |
||||||
| Storage Temperature | -30°C -- +70°C |
Packing Size |
40.5x22x13.5cm |
||||||
| Warranty | 18 months |
N.W. / G.W. (KG) |
2.6KG/3.2KG |
||||||
| Start | Bipolar soft-start |
Quantity / Carton |
6pcs |
||||||
| Cooling Way | Intelligent cooling fan |
Carton Size |
46x42x43cm |
||||||
| Certification | CE, E-mark, FCC, ROHS |
Carton Weight |
20.0KG |
||||||